Shinestar STEEL GROUP CO., LTD

盛仕达 钢铁 股份有限公司

Tuyaux en acier galvanisé

Brève description:


  • Mots - clés: Carbon Steel Pipe, Electric Resistance Welded Steel Pipe, Round Pipe,Square Pipe, Rectangular Pipe
  • Taille: OD: 21.3mm ~ 610mm; WT: 0,5 mm ~ 20 mm, longueur: 0.3mtr ~ 18mtr, Longueur Ramdon, Longueur fixe, SRL, DRL
  • Standard & Grade: GB / T 3091 Q195 / Q215 / Q235 / Q345, BS 1387, EN 39, EN 1139 S235JR / S275JR, ASTM A53 GR. A / B / C, JIS G3444 STK 400/500 STK
  • Fin: coupe carrée / fileté, Burr Removed
  • Emballage: Steel Strips Bundled, Plastic Caps Plugged, Waterproof Paper Wrapped etc
  • Utilisation: Used for Transporting Low Pressure Liquid, Gas And Heating
  • Application: le Widely Used in Furniture, Interior Decoration, Structure
  • Détail du produit

    spécification

    la norme

    Peinture et Revêtement

    Emballage et chargement

    1. What are galvanized pipes?
    Galvanized pipes are steel pipes that have been dipped in a protective zinc coating to prevent corrosion and rust. Galvanized piping was commonly installed in homes built before 1960. When it was invented, galvanized pipe was an alternative to lead pipe for water supply lines. Today, however, we have learned that decades of exposure to water will cause galvanized pipes to corrode and rust on the inside.

     

    2. Galvanized seamless pipe is divided into cold-plated steel seamless pipe and hot dip seamless pipe.

    conduite par immersion à chaud sans soudure

    Le tuyau sans soudure est de rendre la réaction du substrat de métal fondu et de fer, la couche d'alliage, de sorte que la combinaison du substrat et le revêtement des deux. la galvanisation à chaud est le premier décapage de l'acier, afin d'enlever la surface du tube d'acier de l'oxyde de fer, de décapage, une solution aqueuse de chlorure d'ammonium ou le chlorure de zinc ou le chlorure d'ammonium et le chlorure de zinc de nettoyage mixte du réservoir de solution aqueuse, puis l'envoyer dans la chaude cuve d'immersion. par immersion à chaud uniformité du revêtement galvanisé, forte adhérence et longue vie.

    tubes sans soudure à froid plaqué

    Froid galvanisé, électrique galvanisé, galvanisé la quantité de petite, seulement 10-50g / m2 de sa propre résistance à la corrosion que les tuyaux galvanisé à chaud beaucoup de différence. fabricants de tuyaux galvanisés réguliers, afin d'assurer la qualité, la plupart ne pas utiliser électrique galvanisé (à froid plaqué). Seuls ceux à petite échelle, des équipements obsolètes et les petites entreprises avec galvanisées électrique, bien sûr, leurs prix sont relativement pas cher. Le Ministère de la construction a formellement ci-dessous, tuyau en acier galvanisé à froid pour éliminer la technologie vers l'arrière, l'avenir ne sera pas autorisé à tuyau en acier galvanisé à froid pour l'eau, les conduites de gaz.

     

    3. Galvanized seamless mechanical properties

    Les propriétés mécaniques de l'acier est de veiller à ce que un indicateur important des propriétés d'utilisation finale acier (propriétés mécaniques), cela dépend de la composition chimique et le traitement thermique de l'acier. les normes de l'acier, en fonction de différentes exigences, les dispositions des propriétés de traction (résistance à la traction, limite d'élasticité ou allongement limite d'élasticité) et la dureté, la ténacité, exigences des utilisateurs, haute et basse performances de la température.

     

    4. How long do galvanized pipes last?
    No piping system lasts forever, but galvanized pipes have a life span of between 40 to 100 years. If your home’s pipes are from the 1960s or earlier, they are likely nearing the end of their functional life span. However, there’s a reason galvanized pipes are no longer used in modern construction: the risk they pose to a home’s water supply and people’s health.

     

    5. Are there safety risks or concerns with galvanized piping?
    By far, the most significant problem related to galvanized pipes is the mineral deposits that accumulate within the piping. Over time, it causes a reduction in water pressure and pollutes your home’s water. And as rust and corrosion deepen, they compromise the piping system’s stability and cause leaks.

    As old and corroded galvanized pipes age, they can release accumulated lead into your tap water. That lead can pose significant health concerns, as ingesting too much can result in lead poisoning, and its symptoms include fatigue, headaches, insomnia, nausea, constipation, abdominal pain, and reduced cognitive abilities. High doses of lead are of particular concern with children, as it can hinder their brain development and lead to lifelong health issues.


  • Précédent:
  • Next:

  • Application:

    1. Construction et matériau de structure
    2. des fins d'ingénierie et .Mechanical générales
    3. Fabrication de corps Bus, Boogies ferroviaires
    4. Dans le département téléphonique comme Pipes Conduit

    Matériel d'inspection (tuyaux en acier) - Suspension - Dégraissage - Rinçage - Décapage - Lavage - Tremper Fluxage - air chaud Séchage - A l'intérieur et à l'extérieur par immersion à chaud Galvanisation Coup

    - Refroidissement - passif et Rising - Déchargement - Inspection et taillage - Type d'identification - Emballage et stockage et transport

    Types: Galvanized welded steel pipe, galvanized seamless steel pipe
    Materials: Carbon steel
    Connection type: threaded
    Size range:1/8″-36″
    Schedule: sch40, sch80, sch120, sch160, XH, XXH

     

    Longueur des tubes galvanisés
    – in diameter 4 – 16 mm 6000 + 100 mm
    – in diameter 18 – 42 mm 6000 + 50 mm

    Tolérances des tubes revêtus de zinc
    – tolerances of the outside diameter:
    – diameter between 4 – 30 mm ±0,08 mm
    – diameter between 35 – 38 mm ±0,15 mm
    – diameter up to 42 mm ±0,20 mm
    – tolerances of the inside diameter are according to EN 10305-4
    – tolerance of the wall thickness ± 10%

    Les nuances d'acier pour les tubes revêtus de zinc
    E 235+N and E 355+N

    le niveau de tuyaux en acier galvanisé

    L' état de surface des tubes galvanisés
    First layer –electrically leached zinc (Zn) – acts as anode and in a corrosive environment it corrodes first and the base metal is cathadically protected against corrosion. The zinc layer thickness may be in the range of 5 to 30 micrometers (µm).

    la garniture d'étanchéité de tuyaux en acier galvaniséemballage unique

    la garniture d'étanchéité de tube 02 en acier galvanisé

     Livraison au port

    la garniture d'étanchéité de tube 03 en acier galvanisé

    transport professionnel

    la garniture d'étanchéité de tube 04 en acier galvaniséemballage professionnel

    la garniture d'étanchéité de tube 05 en acier galvaniséConvient taille de carton

    la garniture d'étanchéité de tube 06 en acier galvanisé

    emballage complet

  • We use cookies to offer a better browsing experience, analyze site traffic, and personalize content. By using this site, you agree to our use of cookies.

    Accept